Barrier Gate Debugging!
- Categories:Knowledge
- Author:
- Origin:
- Time of issue:2014-02-10 15:39
- Views:
(Summary description)Photonic limit switch minitrim We have adjust the photonic limit switch at well work position before selling, no need to adjust again at normal condition. If want to adjust it, please put the pole at vertical or horizontal position, loosen the screws of light blocking layer, and turn it until indicator on. Red color is horizontal limit position; green color is as vertical limit position.
Barrier Gate Debugging!
(Summary description)Photonic limit switch minitrim
We have adjust the photonic limit switch at well work position before selling, no need to adjust again at normal condition. If want to adjust it, please put the pole at vertical or horizontal position, loosen the screws of light blocking layer, and turn it until indicator on. Red color is horizontal limit position; green color is as vertical limit position.
- Categories:Knowledge
- Author:
- Origin:
- Time of issue:2014-02-10 15:39
- Views:
NO. |
Phenomenon |
reason |
Setting way |
1 |
Machine work, barrier pole not work |
Capacity connect to main controller or not Photonics connect to main controller or not |
1.put the two line of capacity connect to main controller front/inverse interface 2.put the 4 lines of photonics limit switch connect to main controller |
2 |
Pole shake when in work procession |
1.spring balance not matching 2.cabinet not fix well |
1.adjusing spring power 2.fix the cabinet well |
3 |
Not vertical or horizontal when pole in place |
Light blocking layer no in right position |
Refer to photonic limit switch mini trim |